EDS® Projects

 

EDS Project

 

Data Centre Power Generation
Amazon, Dublin
Thermal and airflow simulation of 24MW power generation enclosure to provide efficient passive cooling, avoiding generator derating. New Build.
Passive Design • Thermal Simulation • Performance Analysis • CFD

 

EDS Project

 

Clare County Council HQ
Ennis, Co. Clare
Full Design and implementation of Natural Ventilation & control system commissioning.
Passive Design • Thermal Simulation • Natural Ventilation • Performance Analysis • CFD

 

EDS Project

 

Speculative Office Complex
Cuffe Street, Dublin
USGBC LEED Gold facade design and compliance of air conditioned office complex. New Build.
Passive Design • Thermal Simulation • Performance Analysis • CFD

 

EDS Project

 

Large Suburban Residential Complex
Carrickmines, Dublin
Airflow/wind analysis through large suburban development. New Build.
Large External Site CFD

 

EDS Project

 

Government Department Offices
Intreo, Galway
Full Design and implementation of cellular Natural Ventilation & control system commissioning. New Build.
Passive Design • Thermal Simulation • Natural Ventilation • Performance Analysis • CFD

 

EDS Project

 

Speculative Office Complex
Co. Meath
Overheating, Shading, and Daylight analysis. New Build.
Passive Design • Thermal Simulation • Design Validation • Performance Analysis • Daylight Simulation

 

EDS Project

 

Double Skin Facade
Messian Plaza, Dublin
CFD Analysis of Double-Skin-Facade detail on landmark commercial building in Dublin.
Passive Design • Thermal Simulation • Design Validation • Performance Analysis • CFD

 

EDS Project

 

Community Care Centre
Birr, Co Offaly
Building & systems performance analysis. Heat loss, draught & leak detection. Insulation survey. Solar control. Existing Building.
Passive Design • Design Validation • Performance Analysis

 

EDS Project

 

Smoke/Fire Analysis
Bewleys Cafe, Grafton Street, Dublin
Fire & smoke CFD analysis of landmark commercial building in Dublin. Mechanical extract and airflow analysis. Building Refurbishment.
Passive Design • Thermal Simulation • Design Validation • Performance Analysis • CFD

 

EDS Project

 

Road Safety Authority HQ
RSA, Ballina
Building & systems performance analysis. Heat loss, draught & leak detection. Insulation survey. Solar control. Existing Building.
Passive Design • Thermal Simulation • Design Validation • Performance Analysis

 

EDS Project

 

National Parks & Wildlife Service
Ballycroy Visitor Centre
Building & systems performance analysis. Heat loss, draught & leak detection. Insulation survey. Solar control. Existing Building.
Passive Design • Thermal Simulation • Natural Ventilation • Design Validation • Performance Analysis • CFD

 

EDS Project

 

Government Buildings
Galway City, Co. Galway
Building & systems performance analysis. Heat loss, draught & leak detection. Insulation survey. Solar control. Existing Building.
Performance Analysis

 

EDS Project

 

Primary Care Centre
Mallow, Co. Cork
Full Design & automated control of naturally ventilated Care Centre. New Build.
Passive Design • Thermal Simulation • Natural Ventilation • CFD

 

EDS Project

 

Facade Design
State Street Bank, Dublin
Facade/shading design & material selection. New Build.
Thermal Simulation • Design Validation • CFD

 

EDS Project

 

Open Plan Office Development (HVAC) - Irish Times, Dublin
Thermal Analysis and HVAC design of commercial offices. New Build.
Thermal Simulation • Design Validation • CFD

 

EDS Project

 

Open Plan Office Development
Bank of Ireland, Dublin
HVAC, Active Chilled Beams. Thermal Analysis, Material Selection, Shading and HVAC Design of commercial offices. New Build.
Passive Design • Thermal Simulation • CFD

 

EDS Project

 

Dept of Agriculture, Food and the Marine
National Seafood Centre, Co. Cork
Thermal Analysis, Solar Shading, Design Validation and Natural Ventilation Compliance. New Build.
Passive Design • Thermal Simulation • Natural Ventilation • CFD

 

EDS Project

 

NUIM Library Building (NV/Mixed Mode)
Maynooth, Co. Kildare
Thermal Analysis and Natural Ventilation Design Validation of library building and double skin facade (DSF). New Build.
Thermal Simulation • Natural Ventilation • Design Validation • CFD

 

EDS Project

 

Irish Prison Service Headquarters - Co. Longford, Ireland
Thermal Analysis, Solar Shading, Design Validation and Natural Ventilation Compliance. New Build.
Passive Design • Thermal Simulation • Natural Ventilation • Design Validation • Performance Analysis • CFD

 

EDS Project

 

Open Plan Office Development
Cork City
Thermal Analysis and HVAC design of commercial offices. New Build.
Thermal Simulation • Design Validation • CFD

 

EDS Project

 

Municipal Space & Offices
Dublin City
Thermal Analysis, Material Selection and Shading of public spaces and offices. New Build.
Passive Design • Thermal Simulation

 

EDS Project

 

Impact of Commercial Development on Dwellings
Daylight analysis, impact of commercial proposal on existing dwellings. New Build.
Design Validation

 

EDS Project

 

Open Plan Office
Thermal Analysis, Material Selection and Shading of commercial offices, Co. Dublin New Build.
Thermal Simulation • Design Validation • CFD

EDS® Passive Design

Low Energy, Low Impact, Sustainable Design

The process of Passive Design sets out to reduce or eliminate the requirement for mechanical heating, ventilation & air-conditioning (HVAC) systems.

During the early stages of design EDS® will assist the architect in achieving a passive design and determine potential savings around design proposals.

The balance of maximising daylight to occupied zones while prohibiting solar gains will also help to reduce electrical lighting & cooling demands, promoting a comfortable working/living space.

Climate and other environmental conditions such as rainwater availability, prevailing wind directions, solar radiation, and night cooling will be used to condition the internal environment.

EDS - CFD


The biggest savings may be realised by the implementation of Natural Ventilation (NV) early in the design process.  EDS® NV successfully eliminates the requirement for air-conditioning and mechanical ventilation on many large and medium sized buildings using carefully calculated implementation of natural ventilation techniques; supported by computational fluid dynamic (CFD) calculation methods.

More »

 

EDS® Thermal Simulation

Modelling Cause & Effect

Computer simulation can be used to establish benefits or limitations in advance of changes to design proposals; or changes to the existing built environment. The calculation methods that are typically adopted include:

- Steady State Calculations
- Dynamic Thermal Simulation
- Computational Fluid Dynamics (CFD)

 

EDS - CFD

More »

 

   Make Contact or Request a Call
A phone number or email address is required.

Spam Control
Please complete this simple sum:   4 + 4 =  
(Clue: 4 + 4 = 8 )